Product Showcase

Product Videos    |    Product Presentations    |    Videos & Webinars    |    Product Catalogs


Product Videos

Selected Cain Industries product videos are available for you to download here. 

Additional interactive presentations and video footage is available on CD-ROM.  Please contact Cain Industries sales@cainind.com for more information.

ESG-636L18CSS High performance steam generator.

Capacity: 400kW - 7MW.  Entering gas temperatures:  600°F - 1,600°F.  Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam.  This model recovers heat from a natural gas fired incinerator and produces 228boiler HP steam @125psi.
2:26 / 24MB PLAY VIDEO ESG-636L18CSS

ESG1-816D17CSS  High performance steam generator.

Capacity: 400kW - 7MW.  Entering gas temperatures:  600°F - 1,600°F.  Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. 
2:43 / 23MB   PLAY LOW-RES VIDEO ESG1-816D17CSS

ESG1-816D17CSS  High performance steam generator.

Capacity: 400kW - 7MW.  Entering gas temperatures:  600°F - 1,600°F.  Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. 
7:33 / 76MB   PLAY HIGH-RES VIDEO ESG1-816D17CSS

ESG1-820D17CSS  High performance steam generator.

Capacity: 400kW - 7MW.  Entering gas temperatures:  600°F - 1,600°F.  Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. Shown installed at The Museum of Science and Industry in Chicago, IL.
0:48 / 8MB  PLAY VIDEO  ESG1-820D17CSS

ESG1-616B19CSS  High performance steam generator.

Capacity: 400kW - 7MW.  Entering gas temperatures:  600°F - 1,600°F.  Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. Shown in medical center installation.  Recovering heat from Jenbacher JMS-320 900kW natural gas engines.
0:31 / 5MB  PLAY VIDEO ESG1-616B19CSS

ESG1-616D18CSS  High performance steam generator.

Capacity: 400kW - 7MW.  Entering gas temperatures:  600°F - 1,600°F.  Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. Recovering heat from Cummins QSV91.
1:50 / 15MB   PLAY VIDEO  ESG1-616D18CSS

FCR-1M2A16ALS  Cylindrical boiler economizers. 

Capacity: 50 - 10,000 scfm.  Entering gas temperature up to 1,400°F.   Heat sink types: Boiler feedwater, makeup water, process water, potable water, thermal fluids, run-around systems.  Shown in printing plant installation.
0:15 / 2MB   PLAY VIDEO 1M2A16ALS

HRSR-3Z2H22.6CSS  Radial design waste heat recovery silencer. 

Capacity: 200kW - 6MW.  Entering gas temperatures up to 1,250°F.  Heat sink types: Engine jacket water, process water, boiler water, or glycol.  These horizontal models recovers heat from Wartsilla 18V32BF, 5.8Mw engines.
1:42 / 15MB  PLAY VIDEO  HRSR-3Z2H22.6CSS

HRSR-230B26CSP  Radial design waste heat recovery silencer.

Capacity: 200kW - 6MW.  Entering gas temperatures up to 1,250°F.  Heat sink types: Engine jacket water, process water, boiler water, or glycol.  Vertical units shown here recover heat from Cummins QSK60 diesel engines at a Siberian power plant.
2:37 / 26MB  PLAY VIDEO HRSR-230B26CSP

HRSR-330C26SSP  Radial design waste heat recovery silencer.

Capacity: 200kW - 6MW.  Entering gas temperatures up to 1,250°F.  Heat sink types: Engine jacket water, process water, boiler water, or glycol.  Six vertical units shown here recover heat from Cat 3516 engines.
1:16 / 13MB   PLAY VIDEO HRSR-330C26SSP

HRSR-230C  Radial design waste heat recovery silencer.

Capacity: 200kW - 6MW.  Entering gas temperatures up to 1,250°F.  Heat sink types: Engine jacket water, process water, boiler water, or glycol.  These horizontal models recover heat from engines at the American Embassy in Afghanistan.
3:19 / 34MB  PLAY VIDEO  HRSR-230C

HRSR-324B26CSP and HRSR-324826CSP  Radial design waste heat recovery silencer.

Capacity: 200kW - 6MW.  Entering gas temperatures up to 1,250°F.  Heat sink types: Engine jacket water, process water, boiler water, or glycol.  These vertical models recover heat from 3 diesel generators at a power plant.  
2:19 / 24MB  PLAY VIDEO HRSR-324B26CSP & HRSR-324826CSP

RTR  Rectangular tube waste heat recovery.

Capacity: to 40,000pph (50,000,000Btu/hr input.  Entering gas temperatures 300°F to 1,250°F.  Heat sink types: Boiler feedwater, makeup water, hot water return, hot water storage tank, condensate tank, process water, potable water.  Shown: Large vertical unit
0:29 / 4MB  PLAY VIDEO

UTR1-814G16CSP U-Tube Recovery Unit

This recovery unit is used primarily where confined area restrictions vs heat transfer requirements must be considered as a priority.  

Capacity: 200kW - 10MW.  Entering gas temperatures up to 1,600°F.  Heat sink types: Process water, boiler feedwater, glycols, thermal transfer fluids.  Recovering heat from a 1500kW Fairbanks Morse natural gas engine.
0:49 / 7MB  PLAY VIDEO

Sootblower

This video demonstrates the exclusive Cain Fully Automatic Modulating Sootblower.  Shown here on a smaller vertical RTR model.
0:26 / 4MB  PLAY VIDEO

Product Presentations

Selected Cain Industries interactive presentations are available for you to download here. Additional presentations, including a compilation disc, are available on a FREE CD-ROM

Complete Cain Industries Product Line

This presentation includes: Cain Solutions (company overview), Gas & Diesel Cogeneration Systems, Boiler Economizer Systems, Fume Incineration Systems, and Finned Tubing.
123 MB, DOWNLOAD PRESENTATION   estimate 12 minutes.

ESG-636L18CSS Presentation

One of several components supplied by Cain Industries for a complex application.  This ESG recovers 7,636,500 Btu/hr from a natural gas fired incinerator,producing 228 boiler HP at 125psi for an annual cost savings of more than $200,000.
26 MB, DOWNLOAD PRESENTATION   estimate 5 minutes.

ESG1-820D17CSS, ESG1-616D18CSS Presentation

Reducing exhaust gas temperature from 941°F to 346°F at 4,761 SCFM with 1.71WC" pressure drop.  Recovering 3,467,300Btu/hr.  Saving $138,690 annually.

Reducing exhaust gas temperature from 912°F to 422°F at 4,587SCFM with a 1.5WC" pressure drop.  Recovering 1,800,000Btu/hr.
36 MB, DOWNLOAD PRESENTATION   estimate 6 minutes.

FCR-1M2A16ALS Presentation

Recovering 630,128 Btu/hr from 500HP boilers. Reducing exhaust gas from 400 °F to 263°F. at 4,205 SCFM.  Annual cost savings of $96,816.
72MB, DOWNLOAD PRESENTATION  estimate 8 minutes.

HRSR-3Z2H22.6CSS Horizontal Presentation

Recovering 7,764,000 Btu/hr at 15,857 SCFM. Reducing exhaust gas from 716 °F to 310 °F. Annual cost savings of over $100,000.
24MB, DOWNLOAD PRESENTATION  estimate 5 minutes.

HRSR-32428CSP / HRSR-330C28CSP Presentation

(2) HRSR-32428CSP, recovering heat from Cat 3516 1200rpm engine - lowering exhaust temp from 904 °F to 358 °F.   (1) HRSR-330C28CSP, recovering heat from Cat 3516B 1800 rpm engine - lowering exhaust temp from 979 °F to 374 °F. Combined recovery of 5,010,000Btu/hr for an annual savings of over $150,000
23MB, DOWNLOAD PRESENTATION  estimate 5 minutes.

RTR-1V2126.7CSS Horizontal Presentation

Reducing exhaust gas from 509°F to 343°F. at 14,047 SCFM.  Recovering 3,451,700 Btu/hr for an annual cost savings of $96,816.
8MB, DOWNLOAD PRESENTATION  estimate less than 1 minute.

RTR-1Y2128CSS Vertical Presentation

Retrofitting a 150,000 lb/hr boiler and reducing exhaust gas from 635 °F to 369°F. at 36,521 SCFM.  Recovering 1,716,000 Btu/hr for an annual cost savings of $403,000.
59MB, DOWNLOAD PRESENTATION  estimate 7 minutes.

UTR1-814G16CSP Presentation

Recovering heat from Fairbanks-Morse natural gas fired engines.  Reducing exhaust gas temperature from 645°F to 357°F at 6,739 SCFM with a 2WC" pressure drop.  Raising liquid from 250°F to 263.3°F at 400GPM.  Recovering 2,340,700Btu/hr, saving $60,000 annually.
12MB, DOWNLOAD PRESENTATION estimate 2 minutes.

 

Cain Industries is ASME and National Board Certified